With predictive energy modeling, Northeast Projects simulates a building's performance before it's constructed.  The criteria below represent a typical conventional home built in the Northeast to illustrate the achieved reductions in energy consumption.

Type

iCFA

Climate 

Single-Family

2,500 ft2

5a

Surface / iCFA

Heating Demand

Cooling Demand

Heating Load

Cooling Load

Source Energy

3.6

28.87 kBTU/ft2.yr

8.89 kBTU/ft2.yr

19.77 BTU/hr.ft2

4.91 BTU/hr.ft2

10,298 kWh/ea.yr

2018 PHIUS Design Competition

Honorable Mention: Residential

 

Accord Passive House

Strone Ridge, NY

/// North River Architecture & Planning

DSC_2496.1.1.1.jpg
Accord Passive House

Accord, NY

PH logo.jpg

Type

iCFA

iCFA

iCFA

Surface / iCFA

Heating Demand

Cooling Demand

Heating Load

Cooling Load

Source Energy

Single-Family

2,755 ft2

6

2.785

5.76 kBTU/ft2.yr

.96 kBTU/ft2.yr

4.31 BTU/hr.ft2

2.19 BTU/hr.ft2

5,441 kWh/ea.yr

Newburgh's First Passive House

 

North Miller Passive Multifamily

Newburgh, NY

/// Michael Robinson, Passive Builder

20190530_197 N Miller_Render.jpg
North Miller Passive Multifamily

Newburgh, NY

PH logo.jpg

Type

iCFA

iCFA

Climate 

Surface / iCFA

Heating Demand

Cooling Demand

Heating Load

Cooling Load

Source Energy

Multi-Family

2,354

5a

2.312

5.59 kBTU/ft2.yr

4.43 kBTU/ft2.yr

5.49 BTU/hr.ft2

3.37 BTU/hr.ft2

729 kWh/ea.yr

Balanced Builders Passive Office

Newburgh, NY

PH logo.jpg

Type

iCFA

iCFA

Climate 

Surface / iCFA

Heating Demand

Cooling Demand

Heating Load

Cooling Load

Source Energy

Commercial

972

5a

4.372

8.05 kBTU/ft2.yr

3.99 kBTU/ft2.yr

7.6 BTU/hr.ft2

2.84 BTU/hr.ft2

12.2 kBTU/ft2.yr

Gates House

Type

iCFA

Climate

Single-Family

2,464 ft2

5a

Surface / iCFA

Heating Demand

1.969

6.16 kBTU/ft2.yr

Rhinebeck, NY

Cooling Demand

Heating Load

Cooling Load

Source Energy

.76 kBTU/ft2.yr

4.57 BTU/hr.ft2

.95 BTU/hr.ft2

9,223 kWh/ea.yr

Mullet Hall

Type

iCFA

Climate 

Single-Family

2,214

5a

Surface / iCFA

Heating Demand

2.714

8.85 kBTU/ft2.yr

Cold Spring, NY

Cooling Demand

Heating Load

Cooling Load

Source Energy

.72 kBTU/ft2.yr

5.87 BTU/hr.ft2

2.27 BTU/hr.ft2

6,362 kWh/ea.yr

Hill House

Type

iCFA

Climate 

Single-Family

2,686 ft2

5a

Surface / iCFA

Heating Demand

2.448

5.51 kBTU/ft2.yr

New Paltz, NY

Cooling Demand

Heating Load

Cooling Load

Source Energy

1.34 kBTU/ft2.yr

4.75 BTU/hr.ft2

1.33 BTU/hr.ft2

7,761 kWh/ea.yr

Smith-Strauss

Type

iCFA

Climate 

Single-Family

805 ft2

5a

Surface / iCFA

Heating Demand

4.655

8.73 kBTU/ft2.yr

Stone Ridge, NY

Cooling Demand

Heating Load

Cooling Load

Source Energy

2.63 kBTU/ft2.yr

6.93 BTU/hr.ft2

3.09 BTU/hr.ft2

6,485 kWh/ea.yr

Tobin Tocci

Type

iCFA

Climate 

Single-Family

2,146 ft2

5a

Surface / iCFA

Heating Demand

3.336

7.03 kBTU/ft2.yr

Accord, NY

Cooling Demand

Heating Load

Cooling Load

Source Energy

2.75 kBTU/ft2.yr

5.28 BTU/hr.ft2

3.52 BTU/hr.ft2

20,192 kWh/ea.yr